• Location:Home - Highly adhesive type
  • High performance solvent type adhesive

PRODUCTS

Product Category

Single/Double-sided adhesive
Label series
Protective film series
Optics series


Products >> Single/Double-sided adhesive >> Highly adhesive type > Y-1400 series

Product introduction

● Two-component acrylics adhesive
● It has strong adhesive force especially on alkene materials. It is applicable to double sided tape

 

 Physical characteristics

Model

Y-1400

Y-1401

Y-1410

Y-1420

Appearance

Faint yellow transparent thick liquid

Solid ingredient(%)

46.0±1.0

47.0±1.0

40.0±1.0

34.0±1.0

Viscosity(cP/25℃)

5000-9000

5000-9000

7000-15000

7500-13500

Solvent

Toluene·Ethyl Acetate

 

 Mechanical property

Model

Y-1400

Y-1401

Y-1410

Y-1420

Curing agent

Y-101+T0

=0.9%+0.9%

Y-101+T0

=0.9%+0.9%

Y-101+T0

=0.48%+0.48%

Y-101+T0

=0.36%+0.36%

Adhesive force(gf/25mm)

1300-1600

1300-1600

1500-1900

1100-1500

Retentivity(mm)

0-0.7

0-1.0

0-0.3

0-0.4

Initial adhesive force
(steel ball No.)

6-18

4-12

3-8

0-10

Maturation condition

23℃×7day or 40℃×24H

Packaging specification

180kg/ barrel (iron)

 

 Test methods

1.Test material SUS304, testing environment 23℃/65%RH
2.Structure: 25μm PET+25μm dry PSA
3.Adhesive power: 180° stripping (300mm/min) after 20min
4.Retentivity: Fitting area 20mm×20mm, load 1Kg, 40℃×1h. Read the falling distance  of rubber surface
5.Initial adhesive force: Testing result of J.Dow Law is the steel ball number

 

 Application method

The adhesive is applicable to single or double-sided pressure sensitive adhesive tape of various materials.
Mix treatment: Take the same weight of Y - 101 and TO, stir sufficiently, then slowly add to adhesive in stirring condition, and continue stirring for 20 minutes
Drying condition: 80-100℃
1-2min25μm dry

 

 Storage

Storage condition: 5-30℃ shady and cool place with good ventilation conditions
Storage period: Half a year

 

 

 

 Data involved in the abovementioned product information is within the specification range of actual testing value after modification.